中国临床研究:2020,33(3):405-407
本文二维码信息
码上扫一扫!
全膝关节置换术中骨科医生噪声暴露水平的测量与分析
(1.华北理工大学附属遵化市人民医院麻醉科,河北 遵化 064200;2.华北理工大学附属遵化市人民医院内分泌科,河北 遵化 064200;3.华北理工大学附属遵化市人民医院骨二科,河北 遵化 064200;4.华北理工大学附属遵化市人民医院外一科,河北 遵化 064200)
Analysis of noise exposure level of orthopaedic doctors during total knee arthroplasty
摘要
本文已被:浏览 642次   下载 364
投稿时间:2019-06-27   网络发布日期:2020-03-20
中文摘要: 目的 通过测量全膝关节置换术中骨科器械产生的噪声,分析骨科医生的噪声暴露水平。方法 在2018年3月至12月遵化市人民医院择期行初次单侧全膝关节置换术的40台手术中,采用声级计测量和记录术中不同操作过程中术者所受骨锤(股骨远端截骨、胫骨平台截骨、股骨四合一截骨、股骨髁间截骨、胫骨平台打桩5项)和摆锯(股骨远端截骨、胫骨平台截骨、股骨四合一截骨和股骨髁间截骨4项)产生的噪声强度和累积时间。结果 实际完成了40台全膝关节置换术过程的测定,其术中骨锤和摆锯噪声超过国家标准。股骨远端截骨、胫骨平台截骨和胫骨平台打桩室骨锤的噪声强度较高,等效声级均在90 dB(A)以上,胫骨平台打桩时骨锤产生的噪声最大声级(107.2±5.2)dB(A)。股骨远端截骨和股骨四合一截骨时摆锯的噪声强度较高,等效声级均在90 dB(A)以上,股骨四合一截骨时摆锯产生的噪声最大声级(106.9±7.8)dB(A)。结论 全膝关节置换术中骨科医生的噪声暴露强度对听力系统有潜在危害,医护人员应提高对噪声污染的认识,增强防护意识。
Abstract:Objective To measure the noise generated by orthopedic instruments during total knee arthroplasty to analyze noise exposure level of orthopedic surgeons. Methods In 40 primary operations of unilateral total knee arthroplasty from March to December 2018, sound level meter was used to measure and record the noise intensity and cumulative time generated by bone hammer (distal femur osteotomy, tibial platform osteotomy, four in one femur osteotomy, intercondylar femur osteotomy, tibial platform piling) and swing saw (distal femur osteotomy, tibial platform piling, four in one femur osteotomy, intercondylar femur osteotomy) in different operation processes. Results The noise of bone hammer and swing saw in 40 total knee arthroplasty exceeded the national standard. The noise intensity from bone hammer in the distal femur osteotomy, tibial plateau osteotomy and tibial platform piling was higher, with the equivalent sound level above 90 dB(A), and the maximum noise level generated by the bone hammer in the tibial platform piling was (107.2±5.2) dB(A). The noise intensity of swing saw in distal femur osteotomy and four in one femur osteotomy was higher with the equivalent sound level over 90 dB(A), and the maximum noise level from four in one femur osteotomy was (106.9±7.8) dB(A). Conclusion The noise exposure of orthopedic surgeons during total knee arthroplasty has potential harm to the hearing system. Medical staff should increase awareness of noise pollution and enhance the awareness of protection.
文章编号:     中图分类号:    文献标志码:B
基金项目:河北省卫健委课题项目(20191737)
引用文本:
刘志杰,华文芳,肖军,等.全膝关节置换术中骨科医生噪声暴露水平的测量与分析[J].中国临床研究,2020,33(3):405-407.